VT-RTA-168D slide

Buy VT RTA-168D

VT RTA-168D
VT RTA-168D (US$549.95)

PC based Ultra-Low-Noise USB Real Time Acoustic Analyzer, Sound Level Meter, Distortion Analyzer, Polarity Tester
Find out more: Manual

Click here to download and try the fully functional Multi-Instrument software using your sound card as the ADC and DAC device!

Package Contents

  1. USB measurement microphone and its accessories (a windshield, a microphone clip and a small microphone stand)
  2. USB cable (2m)
  3. CD (contains the copy-protected Multi-Instrument Software)
  4. USB hardkey (contains a Multi-Instrument Pro License)
  5. Audio Test WAV files (contains a list of audio test tones and noises)
    Download Link: AudioTestCD.rar, AudioTestCD.zip
  6. 1/8” TRS cable (1.8m)
  7. Black Soft Pouch Case
  8. Unique Sound Level Calibration Data (in CD)
  9. Unique Microphone On-Axis and 90-degree Calibration Data (in CD)

Unique Calibration File Download:

Serial Number (7 Digits XXXXXXX)


Specifications

General
Transducer Type 1/2" low-noise pre-polarized condenser on 60 UNS thread
Polar Pattern Omni-directional
Frequency Range 10Hz ~ 20kHz (±1dB with the frequency response calibration file loaded)
Useful Range: 1Hz ~ 90 kHz
Sampling Rate 44.1kHz, 48kHz, 88.2kHz, 96kHz, 176.4kHz, 192kHz
Bit Depth 32 Bit (120 dB SNR ADC)
Number of Input Channels 1
Frequency Accuracy 0.01%
Frequency Weighting Flat, A, B, C, ITU-R 468
Time Weighting Linear, Exponential
(Equivalent Continuous Sound Level (Leq) fully complies with IEC61672)
Max. SPL (THD<1%, 1kHz) 125 dBSPL @ 0dB analog gain
Sound Level Measurement Range 25dB ~ 125dB (typical), adjustable through software gain slider. Recalibration is not required after the gain setting changes.
Sound Level Measurement Accuracy ± 0.3 dB at 94dB, 1kHz after calibration
Sound Level Calibration Calibrated using Type 1 Sound Level Calibrator
Octave Analysis 1/1, 1/3, 1/6, 1/12, 1/24, 1/48, 1/96
(Complies with IEC61260)
Other Functions THD, THD+N, SINAD, SNR, SMPTE IMD, DIN IMD, CCIF2 IMD, Frequency Response, etc.
Much more functions are described in the software manual.
USB Audio USB Audio Class 2.0 (driver installation required)
Connector USB Type C socket
Case Material Aluminum
Weight 150 g
Dimensions Φ21.0 x 185.0 mm
Power Supply USB bus powered (5V)
System Requirements Windows XP/VISTA/7/8/8.1/10/11, 32 bit or 64 bit. Minimum Screen Resolution: 1024 x 600
Calibration Individually calibrated. Calibration files for on-axis and 90 degree included.
RTA 168D Frequency Response

Typical Frequency Response

Examples

Magnitude-Frequency-Response-using-Pseudo-Pink-Noises
Magnitude Frequency Response Measurement using Octave Analysis with Periodic Pink Noise Excitation (no averaging is required unlike the case of pink noise)
RT60-InterruptedNoiseMethod
Measurement of Reverberation and Its Related Acoustic Parameters using the Interrupted Noise Method (Note: Multi-Instrument Pro or above is required)
RT60-Integrated-Impulse-Response-Method
Measurement of Reverberation and Speech Intelligibility Parameters using the Integrated Impulse Response Method (Note: Multi-Instrument Pro or above is required)
RT60-STI-Integrated-Impulse-Response-Method
(cont.) Measurement of Reverberation and Speech Intelligibility Parameters using the Integrated Impulse Response Method (Note: Multi-Instrument Pro or above is required)
Glitch_Detection
Discontinuity Measurement for Detection of Glitch, Digital Dropout, Speaker Rub and Buzz (Note: Multi-Instrument Pro or above is required)
White-Noise-Loudness-Loudness-Level-Sharpness
Sound Quality Measurement Example - Loudness, Loudness Level, Sharpness of a white noise in a Free Field (Note: Multi-Instrument Pro or above is required)
RTA-168D-Parking-Sensor-Ultrasonic-Pluse
Detection of Ultrasound Burst (about 40 kHz ) Emitted by Car Parking Sensor